Configure imported schedules
- Last Updated: August 5, 2026
- 1 minute read
- Automate MFT
- Documentation
MOVEit Automation stores schedule times using the local timezone of the machine where
MOVEit Automation is running. Automate MFT imports every
supported schedule as UTC and emits
TIMEZONE_ASSUMED_UTC; it does not automatically preserve the MOVEit
Automation machine's local timezone.
If the MOVEit Automation machine was not configured to use UTC, the user must:
- Open each imported schedule in Automate MFT.
- Set the schedule's Time Zone field to the timezone that MOVEit Automation used.
- Verify the displayed times, day boundaries, and any repeat windows.
- Confirm the task is activated as intended after the schedule correction, because
imported tasks have
AutoRunEnabled = false.
This is required even when the schedule entity is reused, because the expected timezone must be verified against the source environment.