R&D Activity Displays

The R&D Activity displays provide tables of general information regarding database activity. The pages of activity displays end with this prompt:

Enter <return>, A, L, R, S, U, Z, P, T, or X (? for help): 

The table below describes the actions PROMON takes, based on the input received.

Table 1. Activity display prompt
If you type . . . PROMON will . . .
ENTER Display the next page of the current display if one exists, otherwise return to the previous menu.
A Activate auto-repeat mode. The current display restarts after the number of seconds specified by the current display pause time. Auto-repeat mode stops after the number of times specified by the auto repeat count or when CTRL+C is pressed.
L Load activity counters from start of session. Use this option to reset the activity counters after a sampling a smaller time slice.
R Repeat the current display.
S Sample activity counters for the number of seconds specified by the sampling interval. The current display then restarts. The data shown include only activity which occurred during the sample interval.
U Update activity counters. The current display then restarts. The data shown include changes which occurred since the initial set of data was collected.
Z Zero the activity counters so updates show changes from this time forward.
P Return to the previous menu.
T Return to the top-level (main) menu.
X Exit from the OpenEdge Monitor utility.
? Display help about the entry choices.