The R&D Activity displays provide tables of general information regarding database activity. The pages of activity displays end with this prompt:
|
The table below describes the actions PROMON takes, based on the input received.
| If you type . . . | PROMON will . . . |
|---|---|
| ENTER | Display the next page of the current display if one exists, otherwise return to the previous menu. |
| A | Activate auto-repeat mode. The current display restarts after the number of seconds specified by the current display pause time. Auto-repeat mode stops after the number of times specified by the auto repeat count or when CTRL+C is pressed. |
| L | Load activity counters from start of session. Use this option to reset the activity counters after a sampling a smaller time slice. |
| R | Repeat the current display. |
| S | Sample activity counters for the number of seconds specified by the sampling interval. The current display then restarts. The data shown include only activity which occurred during the sample interval. |
| U | Update activity counters. The current display then restarts. The data shown include changes which occurred since the initial set of data was collected. |
| Z | Zero the activity counters so updates show changes from this time forward. |
| P | Return to the previous menu. |
| T | Return to the top-level (main) menu. |
| X | Exit from the OpenEdge Monitor utility. |