Adjust Page Writer Options
- Last Updated: February 11, 2026
- 1 minute read
- OpenEdge
- Version 13.0
- Documentation
Adjust Page Writer Options
Lets you manually override APW behavior. (This is rarely necessary. Do not change these options unless directed to do so by Technical Support.)
PROMON Adjust Page Writer Options menu
The following shows a sample Adjust Page Writer Options menu.
|
Choose one of the following options:
-
APW queue check time — Allows you to dynamically adjust the value of the Page
Writer Queue Delay (
-pwqdelay) parameter.Note: Though you can set the value of-pwqdelay, it is a self-tuning parameter. When the database encounters heavy loads,-pwqdelaydecreases its value so that the APW writes more often. When the demand on the database lessens,-pwqdelayincreases its value so that the APW writes less often. The default value, in milliseconds, for-pwqdelayis 100. -
APW buffers scan time — Allows you to dynamically adjust the value of the Page
Writer Scan Delay (
-pwsdelay) parameter. The default value, in seconds, for-pwsdelayis 1. -
APW buffers per scan — Enables you to dynamically adjust the value of the Page
Writer Scan (
-pwscan) parameter. -
APW writes per scan — Enables you to dynamically adjust the value of the Page
Writer Maximum Buffers (
-pwwmax) parameter.