When the isolation level is Read Committed and a SELECT FOR UPDATE statement is issued against some data stores, the OpenAccess SDK Client does not lock the expected row.

Valid values

0 | 1

  • 0=The appropriate row will be locked. Specifying 0 degrades the performance for SELECT FOR UPDATE statements because rows are fetched one at a time.
  • 1=The appropriate row is not locked.

Default

1

Type

Dynamic

For more information about isolation levels, refer to the OpenAccess SDK Client Reference.