To edit an existing device, select the device on the left and click the pencil icon at the bottom of the screen. Make the changes as needed and click Apply to apply the changes.
If your initial connection fails and you need to use an alternate address to access the UI, type the address in the Alternate WUI Access field and click Apply. This is generally applicable in an Azure and AWS environment or if you have configuration problems with your LoadMaster.
When you modify a device’s IP address, the list of networks shown in the Network drop-down list only contains networks whose IP address range contains the specified IP address. For example, you have two networks, 10.0.0.0/24 and 192.168.0.0/24, and you modify a device's IP address from 10.0.0.11 to 192.168.0.11. After you do this, only the 192 network appears in the Network drop-down list and not the 10 network.
If you are editing a LoadMaster HA pair, you must do it at the shared IP level. In addition, you must ensure that the parameters you provide are valid because they are checked by Kemp 360 Central. Therefore, you must use the correct IP address, correct credentials, and port numbers. If everything is set up and correct, it is verified by the system. If you want to delete a LoadMaster HA pair, you must delete the shared IP address. If you try to delete an individual LoadMaster, you will not be able to.