A silent installation configuration file is a text file that you create, for example, silent.properties. This file must contain the following arguments:
## Use the hash mark for comments in the file
USER_INSTALL_DIR=install_dir
EVAL=0
LICENSED=1
USERNAME=user_name
COMPANYNAME=company_name
SERIALNUMBER=xxxxxxxx
INSTALL_OPTIONS_CREATE=(0 | 1)
KEYLIST=yyyyyyyyyy
## Optionally, overwrite a specific file
-fileOverwrite_filename=(Yes | No)
The following table describes the keyword-value pairs used when creating a response file.
| Keyword | Description |
|---|---|
USER_INSTALL_DIR |
specifies the product installation directory. Notice that
the colon (:) and backslash (\) special characters must be escaped with a backslash.
For example: C:\\Program Files\\Progress\\DataDirect\\ODBC_80 |
EVAL |
Specifies whether this is an evaluation install. Type 0 to specify a licensed installation. Note that the silent installation method does not support evaluation installs. |
LICENSED |
Specifies whether this is a licensed install. Type 1 to specify a licensed installation. Note that the silent installation method does not support evaluation installs. |
USERNAME |
Specifies the user name that will be written to the license file. For example, type Sales Team as the user name. |
COMPANYNAME |
Specifies the company name that will be written to the license file. For example, type MyCompany. |
SERIALNUMBER |
specifies the product serial number that will be written to the license file. |
KEYLIST |
is your product license key, including dashes. If specifying
multiple keys, separate them using a space. For example: 123-456-7890 234-567-8901 345-678-9012. |
INSTALL_OPTIONS_CREATE |
specifies whether to create default data sources. Type 1 if you want to create default data sources or 0 if you do not want to create default data sources. |
-fileOverwrite_filename |
indicates whether the silent installer should overwite a specific file
(optional). For example, if you are overwriting an existing ODBC installation and
do not want to update the Progress DataDirect ODBC tracing library (C:\Windows\system32\ivtrc28.dll), then include the
following line in the response file:
|
See Performing the Silent Installation for instructions on running the response file.