The Bulk tab allows you to specify DataDirect Bulk Load settings. The fields
are optional unless otherwise noted. On this tab, provide values for the options in the
following table; then, click Apply.
If your application is already coded to use parameter array batch
functionality, you can leverage DataDirect Bulk Load features through the Enable Bulk Load
connection option. Enabling this option automatically converts the parameter array batch
operation to use the database bulk load protocol.
If you are not using parameter array batch functionality, you can export
data to a bulk load data file, verify the metadata of the bulk load configuration file against
the structure of the target table, and bulk load data to a table. Use the following steps to
accomplish these tasks.
To export data from a table to a bulk load data file, click Export Table from the Bulk tab. The Export Table dialog box appears. Figure 2. ODBC SAP ASE Wire Protocol Export Table Driver Setup dialog
box
Table Name: A string that specifies the name of the source database
table containing the data to be exported.
Export
Filename: A string that specifies the path (relative or absolute) and file of the
bulk load data file to which the data is to be exported. It also specifies the file name
of the bulk configuration file. The file name must be the fully qualified path to the bulk
data file. These files must not already exist; if one of both of them already exists, an
error is returned.
Log Filename: A string
that specifies the path (relative or absolute) and file name of the bulk log file. The log
file is created if it does not exist. Events logged to
this file are:
Total number of rows fetched
A message for each row that failed to export
Total number of rows that failed to export
Total number of rows successfully exported
Information about the load is written to this file, preceded by a
header. Information about the next load is appended to the end of the
file.
If you do not supply a value for Log Filename, no log file is
created.
Error Tolerance: A value that
specifies the number of errors to tolerate before an operation terminates. A value of 0
indicates that no errors are tolerated; the operation fails when the first error is
encountered.
The default of -1 means that an infinite number of
errors is tolerated.
Warning Tolerance: A
value that specifies the number of warnings to tolerate before an operation terminates. A
value of 0 indicates that no warnings are tolerated; the operation fails when the first
warning is encountered.
The default of -1 means that an infinite
number of warnings is tolerated.
Code Page:
A value that specifies the code page value to which the driver must convert all data for
storage in the bulk data file. See Character Set Conversions for more information.
The default value on
Windows is the current code page of the machine. On UNIX/Linux, the default value is 4
(ISO 8559-1 Latin-1).
Click Export
Table to connect to the database and export data to the bulk data file or
click Cancel.
To verify the metadata of the bulk load configuration file against the structure of the
target database table, click Verify from the Bulk
tab. See Verification of the Bulk Load Configuration File
for details. The Verify dialog box appears. Figure 3. ODBC SAP ASE Wire Protocol Verify Driver Setup dialog box
Table Name: A string that specifies the name of the target database
table into which the data is to be loaded.
Configuration Filename: A string that specifies the path (relative or absolute) and
file name of the bulk configuration
file.
Click Verify to verify table structure or click
Cancel.
To bulk load data from the bulk data file to a database table, click Load Table from the Bulk tab. The Load File dialog box
appears. Figure 4. ODBC SAP ASE Wire Protocol Load File Driver Setup dialog
box
Table Name: A string that specifies the name of the target database
table into which the data is loaded.
Load Data
Filename: A string that specifies the path (relative or absolute) and file name of
the bulk data file from which the data is
loaded.
Configuration Filename: A string that specifies the path (relative or absolute) and
file name of the bulk configuration
file..
Log Filename: A string that specifies the path (relative or
absolute) and file name of the bulk log file. Specifying a value for Log Filename
creates the file if it does not already exist. Events logged to this file are:
Total number of rows read
Message for each row that failed to load
Total number of rows that failed to load
Total number of rows successfully loaded
Information about the load is written to this file, preceded by a
header. Information about the next load is appended to the end of the
file.
If you do not specify a value for Log Filename, no log file is
created.
Discard Filename: A string that
specifies the path (relative or absolute) and file name of the bulk discard file. The file
name must be the fully qualified path to the discard file. Any row that cannot be inserted
into database as result of bulk load is added to this file, with the last row rejected
added to the end of the file.
Information about the load is written
to this file, preceded by a header. Information about the next load is appended to the end
of the file.
If you do not specify a value for Discard Filename, a discard file is not
created.
Error Tolerance: A value that
specifies the number of errors to tolerate before an operation terminates. A value of 0
indicates that no errors are tolerated; the operation fails when the first error is
encountered.
The default of -1 means that an infinite number of
errors is tolerated.
Load Start: A value
that specifies the first row to be loaded from the data file. Rows are numbered starting
with 1. For example, when Load Start is 10, the first 9 rows of the file are skipped and
the first row loaded is row 10. This option can be used to restart a load after a
failure.
The default value is 1.
Read Buffer Size (KB): A value that specifies the size, in KB, of
the buffer that is used to read the bulk data file for a bulk load operation.
The default value is 2048.
Warning Tolerance: A value that specifies the number of warnings to tolerate before
an operation terminates. A value of 0 indicates that no warnings are tolerated; the
operation fails when the first warning is encountered.
The default
of -1 means that an infinite number of warnings is tolerated.
Load Count: A value that specifies the number of rows to be loaded
from the data file. The bulk load operation loads rows up to the value of Load Count from
the file to the database. It is valid for Load Count to specify more rows than exist in
the data file. The bulk load operation completes successfully when either the number of
rows specified by the Load Count value has been loaded or the end of the data file is
reached. This option can be used in conjunction with Load Start to restart a load after a
failure.
The default value is the maximum value for SQLULEN. If set
to 0, no rows are loaded.
Click Load