Configure the Synapse DICOM Virtual Service
- Last Updated: June 19, 2024
- 2 minute read
- LoadMaster
- LoadMaster GA
- Documentation
- The following are the steps involved and the values required to set up the second of the Fujifilm Synapse Virtual Services:
- In the LoadMaster Web User Interface (WUI) main menu, go to Virtual Services > Add New.
- Enter the same IP address in the Virtual Address text box as you did when setting up the Synapse HTTP Virtual Service in the Configure the Synapse HTTP Virtual Service section.
- Enter 104 in the Port text box.Note: TCP connections on port 104 are recognized as DICOM requests and are forwarded to the DICOM server which the LoadMaster determines is the most available based on processor and memory utilization.
- Enter a recognizable Service Name, for example Synapse DICOM.
- Ensure TCP is selected as the Protocol.
- Click Add this Virtual Service.
- Configure the settings as recommended in the following table:
Section
Option
Value
Basic Properties
Service Name
HTTP/HTTPS
Standard Options
Transparency
Disabled
Subnet Originating Requests
Enabled
Persistence Mode Source IP Address Timeout 1 Hour Scheduling Method resource based (adaptive) Advanced Properties
Added HTTP Headers
None
Real Servers Real Server Check Method TCP Connection Only - Add the Real Servers:
- Click the Add New button.
- Enter the Real Server
Address.Note: This is the address of the backend server.
- Enter 104 as the Port.Note: The Real Server Port should match the Virtual Service Port.Note: The Forwarding method and Weight values are set by default. These can be changed by an administrator.
- Click Add this Real Server. Click OK to the pop-up message.
- Repeat the steps above to add more Real Servers as needed, based on the environment.