This procedure updates the MOVEit Automation server SSL/TLS certificate used by the Automation service. This certificate is configured in the General tab of the Config Utility and is separate from the Web Admin SSL/TLS certificate.

This procedure is specific to the MOVEit Automation Server certificate. To update the Web Admin certificate, see Update the MOVEit Automation Web Admin SSL/TLS Certificate.

Important: This procedure requires restarting the MOVEit Automation service. In failover environments, plan this change carefully to avoid unintended service disruption or to trigger a controlled failover.

Prerequisites

For use in production environments, you should install a certificate from a trusted certificate authority.

Before updating the certificate, ensure that the following requirements are met:
  • The certificate must be in PFX format and include the private key.
  • The certificate must be installed in the Local Machine > Personal certificate store on the server.
  • The certificate must be valid and trusted by clients that connect to the Automation Server.
  • The certificate must be valid for the hostname or IP address used to connect to the Automation Server.
  • If Web Admin connects to the Automation Server, ensure that the server name configured for that connection is valid for the certificate.

If the certificate is not stored correctly or does not include a private key, the Automation service may fail or users may be unable to sign in.

Update the server SSL/TLS certificate

  1. Open the MOVEit Automation Config Utility application.
  2. Select the General tab, followed by the Certificate ellipsis (…) button.
  3. On the Certificate List dialog, expand Local Machine and select My - Personal. A list of certificates in the personal store is displayed. Verify that the certificate appears in this store.
  4. To assign a certificate to the Config, double-click the certificate. Ensure that the selected certificate includes a private key.
  5. Click Apply, then click OK.
  6. To complete the update, restart the MOVEit Automation service. For more information, see Starting and Stopping.

    After updating the certificate, verify that Web Admin and other clients that connect to the Automation Server can establish a connection successfully.

Troubleshooting certificate issues

If you experience certificate-related issues, check the following:

  • If the old and new certificates have the same name, remove the old certificate from the server before completing the update.
  • If the new certificate does not appear in the list, verify that it is installed in the Local Machine > Personal store.
  • If the certificate was imported but is not selectable, verify that it includes a private key.
  • If you updated the Web Admin certificate but still see an expired certificate error when signing in, check the server certificate configured on the General Tab. The error may be related to the server certificate rather than the Web Admin certificate.
  • If a client cannot connect to the Automation Server because certificate validation fails:
    • Verify that the server certificate is valid.
    • Verify the certificate chain and trust configuration.
    • Verify that the hostname or IP address used for the connection is valid for the server certificate.
    • Review the applicable logs for certificate or connection errors.

Where possible, resolve the certificate, trust, or server-name issue rather than disabling certificate validation.

For Web Admin connections, certificate errors for individual Automation Servers can be ignored by configuring central.ignoreCertErrorsHosts. For more information, see config.properties.