Version 8.2
- Last Updated: November 26, 2026
- 2 minute read
- Flowmon Products
- Flowmon
- Documentation
Version 8.02.13
Issues fixed
- Multiple execution of streamd fixed
Version 8.02.12
Issues fixed
Multiple execution of streamd fixed
Check of .nfstat files of DDoS Defender profiles fixed
Version 8.02.11
Issues fixed
- FMC Profiles expiration fixed
Version 8.02.10
Issues fixed
- Unresponsive or very slow GUI fixed
Version 8.02.09
Issues fixed
- Fixed upgrade on brand new platforms
Version 8.02.08
Issues fixed
CVE-2016-5195 (Dirty cow) fix (kernel patch)
FMC - Reports - chapter statistic over shadow profile which is not using all parent profile channels fixed
Minor security fixes
This update will restart the device.
Version 8.02.07
FMC - Active devices - Export to PDF button added
FMC - Correct detection of non-Flowmon TCP IPFIX flow source supported
Issues fixed
FCC Syslog server configuration fixed
FMC Reports - chapter with IP conversation statistic over shadow profile fixed
Version 8.02.06
Issues fixed
- Fixed flow file compression error
Version 8.02.05
Probe can process MAC addresses inside 802.1ah header
FMC - Analysis - Flow sampling can be enabled for processing of huge amount of data.
Issues fixed
HTTP hostname was wrongly parsed in specific cases - fixed
IPv6 firewall rules generated properly
XML configuration can be downloaded on systems with APM plugin installed
Version 8.02.04
Issues fixed
- Forwarding flows using UDP protocol
Version 8.02.03
Issues fixed
- Collector startup process
Version 8.02.02
- Optimization of flow capture by TCP and UDP protocol
Version 8.02.00
- FMC can receive and forward IPFIX TCP and TCP/TLS connection
Sampling of forwarded flows is no longer available on the collector. Sampling will be disabled after the update. If need to sample forwarded flows even after updating, contact our Support team.
CAREFUL: only one flow source can be forwarded via TCP or TCP/TLS connection
IPFIX with variable length items is supported
Cisco AVC HTTP values are supported
FMC - Active Devices - New Overview tab with useful statistics, Lookup form improved, Vendor logos added.
FMD - Widgets from FMC - Active Devices added
FMC - Sources - IP address for SNMP connection can be modified per flow source
FCC - Remote Access - IP access restrictions can be defined
FCC - Remote Access - Firewall is correctly configured for both IPv4 and IPv6
FCC - FMC config - Reports Settings - sampling can be enabled to speed up report computation over huge data.
FMC - Alerts - SNMP trap alert - alert details added into trap
Issues fixed
New flow source is added only if it sends valid flow data
In TACACS+ configuration, password can contain ';' character