This guide describes the requirements for Flowmon appliance deployment:
Configuration of switches/routers (depending on the deployment of the Probe/Collector)
Depending on the planned deployment of the Flowmon solution you may need to configure the following:
SPAN/mirror port of switch/router to monitor traffic going through the device
NetFlow data export to the Collector
Notice: we strongly recommend ensuring the availability of the network administrator who is responsible for the configuration of switches/routers
Prepare the switch/router ports for management ports of Probes/Collectors connection to the LAN
Place in the rack
1U for each probe and collector models 1000 – 6000Pro
2U for each probe 40 000Pro
2U for each collector 12 000Pro
1U for up to 3 rack TAPs
Power (we recommend the backup power supply from the UPS)
1x 110/230V for each probe and non-Pro collector (1000 and 2000)
2x 110/230V for each probe 20 000Pro, 40 000 and 40 000Pro
2x 110/230V for each Pro collector (3000Pro and higher)
1x 110/230V for copper TAP (has its own power adapter including power cable)
Network cables (copper or optical as needed)
Probe
1x cable for management port (copper, RJ45)
1x cable for each monitoring port
(Note: 1 SPAN port needs 1 monitoring port of the Probe, TAP needs 2 monitoring ports of the Probe)
Collector
- 1x cable for management port (copper, RJ45)
TAP
- 1x short cable between TAP and switch/router