Click here for a list of the known issues in OpenEdge 12.3.

The following table lists issues fixed in this release:

Components Item Details
ABLTOOLS OCTA-13943 The OpenEdge.Core.String object's Trim() methods perform a trim but don't assign the value back to the contained object's internal value.
ABLTOOLS OCTA-18159 OpenEdge.Web.WebResponseWriter omits closing Json tags when data contains no-break space characters (ascii A0).
ABLTOOLS OCTA-19777 Using the ABL HTTP client, the client hangs sending /- 70MB JSON data to a PASOE REST service when SESSION:DEBUG-ALERT = TRUE.
ABLTOOLS OCTA-20120 The OpenEdge.BusinessLogic.Query.QueryBuilder feature utilizes the Filter and Query classes for generating dynamic queries from various client (read: front-end) criteria formats. However, when utilizing the QueryBuilder class to generate query phrases, if temp-tables and their fields are sent from a client request as serialized names, these are not properly translated into their real table or field names. This causes the construction of the query phrase to fail and results in an incomplete/incorrect “where” phrase for the resulting dynamic query. This particular issue extends back to OpenEdge 11.7.5 when first introduced within the OpenEdge.BusinessLogic.pl, as well as OpenEdge versions 12.0 through 12.2.
ABLTOOLS OCTA-20296 In OpenEdge.Net.pl, class OpenEdge.Net.HTTP.Filter.Payload.ClientSocketResponseWriter did not handle splitting the CRLF that terminates a header line into 2 packets (chunks). This resulted in the ClientSocketResponseWriter trying to read a string of 0 bytes, which caused an assertion to fail, resulting in the "Start position must be positive" error message.
ABLTOOLS OCTA-20667 When the Clear() method is run on an OpenEdge.Core.Collections.Map object, the Size remains at a non-zero value. This is misleading.
ABLTOOLS OCTA-21275 OpenEdge.Net.pl: OpenEdge.Web.WebRequest.GetHeaders( ) method returns incomplete HTTP header value due to incorrect offset being used.
ABLTOOLS OCTA-21500 When using the method ViaProxy() of the Openedge.Net.HTTP.ClientBuilder and sending an HTTPS request with the Proxy-Authentication header, the connection to the proxy fails with Connection failure for proxy server XX.XX.XX.XX on port XX.
ABLTOOLS OCTA-21646 The OpenEdge 12 Sports2020 database uses the iso8859-1 basic collation.
ABLTOOLS OCTA-22484/PSC00365236 ABL Unit functionality does not handle the case where a developer uses an include file to cover some of the test cases. The test procedures in the include file do not get run.
ABLTOOLS OCTA-22493/PSC00360755 Adding an additional startup parameter to the ABLUnit Run Configuration prevents the configuration from running. There are no errors, but the output result.xml isn't complete.
ABLTOOLS OCTA-22513/PSC00358460 ABL Unit testing fails when using “expected” annotation which has a space behind the closing bracket.
ABLTOOLS OCTA-22583 The OpenEdge.Web.WebResponseWriter writes a duplicate Transfer-Encoding header, and response bodies are also duplicated when the Write() method is called from a webhandler.
ABLTOOLS OCTA-24555 DataObjectHandler returns weird error if a STOP condition is encountered in OperationHandler:execute.
ADE OCTA-3831/PSC00361660 Load via Data Administration not prompting for code page when multiple .d are selected.
ADE OCTA-3909/PSC00362802 Invalid Initial value adding date field in Temp Table Maintenance tool.

When importing a temp table definition file via Temp Table Maintenace Tool an error is generated if the temp table has a field of datatype "Date" with an initial value where day is greater than 12.

ADE OCTA-8508 AppBuilder raise warning 3623 with -checkdbe
ADE OCTA-17439 Deleting a DataAdminService object without NO-ERROR can cause ERROR-STATUS:ERROR and ERROR-STATUS:get-messages to show errors, even though the deletion of the DataAdminService object completed successfully.
ADE OCTA-23916/ADAS-13089/PSC00248419 Importing _aud-event.ad to a Linux machine from a Windows machine gives the error message:

"ttAuditEvent already exists with 0. (132)

and

ERROR: Event id 0 is invalid. It must be >= 320000

Import

process canceled."

ADE OCTA-23924/ADAS-24071 Since upgrading to 11.7.5, can no longer see the field definitions of metaschema tables in Data Dictionary. Receive message "The entered name does not match any table name in this database".
ADE OCTA-23933/ADAS-22575/PSC00362886 When partition policy is created, there is a difference in local index components in Windows and Unix platforms.
ADE OCTA-23968/ADAS-23783 Check-Syntax error 12629 when mixing includes files and classes in Procedure Editor, but "Syntax check: OK" in PDSOE.
ADE OCTA-24001/ADAS-22571/PSC00356078 Recently added index to a table in an online database shows as ACTIVE before being activated by IDXACTIVATE or IDXBUILD.
ADE OCTA-24002/ADAS-17081 BulkLoad returns Bulkload for CLOB/XLOB is not supported in this version of Progress.
ADE OCTA-24054/ADAS-12455 The created domain can not be saved if cursor stopped on any of the built-in domains in the previous menu.
ADE OCTA-24060/ADAS-23659 When generating an incremental dump from a databases using -RO mode, it dumps data fine but gives encryption error even though the TDE is not enabled.
ADE OCTA-24067/ADAS-15911 AppBuilder reports errors 7452, 4058, 560 when opening a window that has a COMBO-BOX using LIST-ITEM-PAIRS with a label and no value:

LIST-ITEM-PAIRS must contain an even number of entries to specify label/value pairs for (7452).

**Attribute LIST-ITEM-PAIRS for the COMBO-BOX has an invalid value of Item 1.

(4058)

Entry 2 is outside the range of list Item 1. (560).

ADE OCTA-24068/ADAS-16044 AppBuilder reports following errors when opening a window in the AppBuilder perspective of PDSOE after formating the code with "Expand keywords":

HEIGHT-PIXELS = 336 not a valid window attribute.

WIDTH-PIXELS = 400 not a valid window attribute.

MAX-HEIGHT-PIXELS = 336 not a valid window attribute.

MAX-WIDTH-PIXELS = 400 not a valid window attribute.

VIRTUAL-HEIGHT-PIXELS = 336 not a valid window attribute.

VIRTUAL-WIDTH-PIXELS = 400 not a valid window attribute.

ADE OCTA-24074/ADAS-22678 DataAdmin initialises with errors 12371/142 and data admin menus fail to render with errors 12371/142.
ADE OCTA-24077/ADAS-16695 Creating a trigger during Create Table in Data Dictionary returns ** FIND FIRST/LAST failed for table _File. (565)
ADE OCTA-24084/ADAS-16696 'Schema Area' appears twice in the 'Area:' dropdown when an index is added to a table.
ADE OCTA-28525/ADAS-17141 When dumping the DF of a table which was created via SQL-92 on the PUB schema and that table contains foreign key constraint(s), the DF generated is empty.
AdminServer OCTA-23907/ADAS-20705 Classic AppServer and NameServer intermittently fail to start when starting AdminServer even though the brokers are set to autostart.
AdminServer OCTA-24042/ADAS-17305 Domain account passwords are limited to 32 characters for AdminServer logins.
DB OCTA-2584/PSC00217061 The Replication Server process cannot be terminated with the dsrutil utility if the Database Service Manager Queue (PICA queue) is full.
DB OCTA-2887/PSC00250482 Remote DB servers fail to spawn with error "(1890) BROKER: could not spawn server" when using the -convmap <convmap-file-name> parameter and a custom convmap.cp file does not reside in $DLC.
DB OCTA-2910/PSC00253958 Clients receive "Error reading/writing socket, ret=n, errno=n (778)" after the database broker's listening port received unexpected network messages.
DB OCTA-3281/PSC00342861 AI File Management reports SYSTEM ERROR: I/O table not initialized. (533), SYSTEM ERROR: bkioRead: I/O table not initialized index 0 (526), and Unable to read extent header, file = , ret = -1 (6074) errors when adding extents online and the /dev/null is specified as the archive directory.
DB OCTA-13066 Remote clients are not able to connect to database servers and the error "Rejecting login – too many users for this server (1334)” occurs when there are indeed available connections.
DB OCTA-13278 The promon utilities reporting of currently connected users for a database with remote clients can be different with regards to the actual number of users connected to the database.
DB OCTA-13882 SQL queries can fail against a Replication target database with a Table/View/Synonym not found (7519) error because a database schema change on the Replication source database is not fully replicated to the target database.
DB OCTA-18370 Multi-Threaded Index Rebuild can create index keys that are too large.
DB OCTA-20259 Database log shows large number of SYSTEM ERROR: lkrels record 7084811 not locked (435) errors.
DB OCTA-19414 PROSHUT with or without the -F option can hang when a locked USR Latch is left behind by a disconnected user.
DB OCTA-19587 Occasionally on the Solaris64 platform the protrace is missing the c stack after crash of _sqlsrv2.
DB OCTA-19604 After a very large purge operation which caused a large amount of index deletions proutil databaseName -C viewB2 became much slower.
DB OCTA-20279 prostrct add fails with error 7125 when trying to add an extent and the path of the extent is already used by a different database. The other database crashes with error 8540. This is a windows only issue.
DB OCTA-21325 A cancelled prostrct add online of AI extents where the area is created but the physical extent is not can cause a query of the _dbstatus VST to error with an empty record.
DB OCTA-22517 When there are many objects in the same Type II storage area (300+ for 4K DBs and 600 for 8K dbs) PROSTRCT STATISTICS may fail with error (210) (14684) when attempting to scan the object blocks for their statistical information. This can be identified by running dbanalys for an area and if the reported _object list block(s) is greater than 1_, prostrct statistics will fail.
DB OCTA-17416 After a storage failure, replication fails to synchronise with error 10716 on EMPTY or ARCHIVED ai extents which cannot be remediated with dsrutil applyextent.
DB OCTA-19592 Notes processed in dsrutil monitor output is showing as a negative integer.
DB OCTA-19758 Replication monitor does not exit cleanly, which ended with message 2527.
DB OCTA-20425 echo %ERRORLEVEL% returns the value 0 after executing %DLC%\bin\dsrutil.bat with a Y pipe input while the expected error value should be 2.
DB OCTA-21518 The "dsrutil -C monitor" utility does not respond to the "disconnect" command if it is in a monitoring loop.
DataServers OCTA-18902 A self-join query in combination with "BY" clause generates an SQL query with an ORDER BY clause on the unique_id_0 index instead of the unique, single field index that exists for the table. Since the change is in compiler layer, this query needs to recompiled to get the new behaviour.
DataServers-ORACLE OCTA-12919 Multiple Oracle errors reported during bind operation when cursors are low.
DataServers-ORACLE OCTA-17163 A query such as DISP CAN-FIND( LAST customer WHERE lookup(NAME,"Fallen Arch Running") > 0) fails to return anything when using DataServer for Oracle.
DataServers-ORACLE OCTA-19555 Query returns wrong data with Oracle Dataserver qt_cache_size,65000 and qt_debug logging enabled.
Generic JMS Adapter OCTA-23912/ADAS-22496 OE JMS ADAPTER HANGS ON SEND2 JMS/IMPL/MESSAGE-HEADER.P
Generic JMS Adapter OCTA-24066/ADAS-21782 OE Adapter for SonicMQ is reading two messages from the server instead of one.
Install OCTA-23966 When installing the ‘OE Workgroup RDBMS', ‘Progress Dev Studio OE'*,* and ‘OE Ultra Controls .NET' as components on Windows platform, OpenEdge Explorer gets installed usually. However, while doing the same scenario through silent installation oemgmt/bin folder is missing and the oem_tailor log not gets created in DLC\\install\\cleanup folder.
Install OCTA-23984/ADAS-14739/PSC00365609 Unable to restore/rollback to the previous OpenEdge Service Pack version as the Setup utility failing to take backup of existing OpenEdge files.
Install OCTA-24017/ADAS-24091 OpenEdge 12.2 Installer creates an incomplete shared.ini file due to which running the netsetup fails with an error - getprofstring failed.
Install OCTA-24037/ADAS-24081 OpenEdge Installation fails during Java Validation when the User TEMP directory constructs a space or a special character. User Name having spaces may also result into this problem.
Install OCTA-24135/ADAS-24584 Running LicenseUpdate Tool results in the error ‘The system cannot find the file specified $DLC\\fcs.tab'. This problem occurs due to OpenEdge Installer failing to copy the fcs.tab file to the DLC path.
Install OCTA-29355 OpenEdge Explorer tailoring fails on Linux with OpenEdge 12.2.1/12.2.2 updates when installing Enterprise RDBMS and PASOE Dev products.
Lang OCTA-20072 In 12.1.0, an ABL client session using join queries may crash. Specifically, if there is a record in memory and within a sub-transaction that same record is read again as part of the result list for the children of a join, the crash may occur.
Lang OCTA-21469 A program that access the _Sequence table will not work properly if you generate the r-code while connected to an OpenEdge 11.X database and try to run the r-code while connected to an OpenEdge 12.X database.
Lang OCTA-21580 When using the double colon notation to refer to a buffer field in a FOR or FIND statement, if the buffer being referred to resides in a database using the previous major OpenEdge release, these statements raise the STOP condition.
Lang OCTA-22223 ABL clients crash when connecting client/server to a read-only, audit-enabled database within a transaction.
Lang OCTA-22532 Comparison with DECIMAL values may return incorrect result on Linux.
Lang OCTA-22620 A FOR EACH query with NO-LOCK and NO-PREFETCH specified on some but not all levels of the join returns incorrect data.
Lang OCTA-29156 When using the startup parameter -rereadnolock, a FOR EACH join on a non-default buffer which uses the FIELDS clause causes subsequent uses of that buffer to improperly continue to use the FIELD clause restrictions.
Lang OCTA-19343 Updating procedure libraries in a WebClient application fails if the DLC environment variable is not set.
Lang OCTA-20945 A character-mode ABL program which hides and subsequently redisplays a browse widget may crash.
Lang OCTA-20960 An ABL window which contains one or more OCX controls may flicker when it's displayed. CPU usage may be high when such a window is displayed.
Lang OCTA-20976 Garbage collection is not occurring for objects passed to the Event Procedure as part of an asynchronous request.
Lang OCTA-21623 The OS-CREATE-DIR statement creates a directory with a corrupted name when the name contains characters which are in the extended range of the ASCII character set (characters with values greater than 127). This issue occurs in the PASOE agent on Windows. This issue also affects the OS-DELETE, OS-RENAME, and OS-COPY statements.
Lang OCTA-21932 The Infragistics UltraCombo control doesn't allow the selection of multiple items which contain a checkbox.
Lang OCTA-22541 An application may crash when images with 8-bit color (256 colors) or 4-bit color (16 colors) are displayed.
Lang OCTA-23166 In an ABL application started using Microsoft RemoteApp and running on a system with multiple monitors the mouse cursor may jump to the right when the mouse cursor shape changes. This can occur when the LOAD-MOUSE-POINTER method is used or when a wait state (started with SET-WAIT-STATE) is cleared.
Lang OCTA-28378 The OpenEdge AVM may become unresponsive when a frame containing a CONTROL-FRAME (with or without a control) is hidden and redisplayed.
Lang OCTA-3994/PSC00364176 Empty initial value lost when transferring dataset from .NET Open Client to AppServer, resulting in all CHARACTER type fields having a default value of unknown.
Lang OCTA-17464 WHOLE-INDEX referenced at the wrong line number in XREF output file when using IF THEN block.
Lang OCTA-18175 Setting SERIALIZE-NAME to 128 or more characters will cause the AVM to crash when SERIALIZE-NAME is referenced, such as when calling WRITE-XML against the temp-table.
Lang OCTA-18667 READ-XML fails with error "Input value: 0 should be yes/no. (87)" when 1 and 0 values are mapped to a LOGICAL temp-table field. 1 and 0 are valid boolean values per XML standards.
Lang OCTA-21276 Java open client application performance may be impacted by the amount of garbage collection caused when processing a response that contains a temp-table or dataset with a large number of fields.
Lang OCTA-2802/PSC00243604 If you use WRITE-XML or WRITE-JSON against a Dataset which has nested data-relations defined, the methods create dynamic queries for the nested relations but do not clean them up.
Lang OCTA-2978/PSC00262126 Using WRITE-FRAGMENT with returned LONGCHAR object created with SAX-WRITER can cause a large memory leak.
Lang OCTA-8410 GetDate, GetDateTime and GetDateTimeTZ methods for JsonbObject and JsonArray return random dates when the parameter value does not match the ISO-DATE format.
Lang OCTA-18909 Case-sensitive fields can be added to dynamic temp-tables only via the ADD-LIKE-FIELD() method. After doing so, the field's CASE-SENSITIVE attribute is TRUE but the behaviour of the field is still case insensitive.
Lang OCTA-19276 STRING-VALUE method ignores case sensitive comparison of temp-table or database table fields.
Lang OCTA-3241/PSC00340335 The compiler does not raise a compile time error when a non-existent field is specified in a field list (FIELDS option) in the Record Phrase.
Lang OCTA-3319/PSC00345174 Error 1987 ("Operation number <n> not supported in this release.") occurs when an image widget with an expression as the filename is displayed from a different procedure than the one which created the image widget. See article for more details:

000066467, Error 1987 when static IMAGE for a FRAME uses FILENAME phrase

Lang OCTA-3706/PSC00358875 Following code fails to return false although documentation states it should return false.

def var i-password as char

initial ?.

message setuserid("ccenms", i-password, "LISA").

Lang OCTA-3936/PSC00363349 The ABL compiler accepts the ASCENDING keyword for the ASC function. This usage should cause an error.
Lang OCTA-9160 A modal form may not be disposed correctly when it is closed, even if the DisposeDialogOnClose property is set to TRUE. Error ".NET is attempting to call a method or access a property in the ABL (e.g. a .NET override) and failed. The object is either a form that has already been disposed or an object that has been explicitly deleted from the ABL. (15580)" is generated when this issue occurs.
Lang OCTA-14638 Assignment of method value raises syntax error 247 if ASSIGN is omitted.
Lang OCTA-14793 When inferring XML schema, the READ-XML method doesn't recognize newly added fields and nested temp-tables in subsequent instances of a temp-table's schema. Only the fields and nested temp-tables in the first instance are recognized.
Lang OCTA-16621 Error 12882 occurs when trying to access ReturnValue from an instance of a class which inherits Progress.Lang.AppError. The error does not occur when referencing THIS-OBJECT:ReturnValue.
Lang OCTA-18273 If upper case letters appear in the hex string passed to TO-ROWID, then the record is not found in an ABL query.
Lang OCTA-20959 The column labels on a report with a frame width of 320 columns may not be formatted correctly. The column labels may be missing or extra blank lines may be inserted in the report.
Lang OCTA-21308 An application crash may happen when the binding source is set with no buffer handles.
Lang OCTA-3722/PSC00359223 The 4GLTrace does not log 'Invoke' entries for static constructors.
Lang OCTA-3876/PSC00362202 Compiling an ABL source file which causes a compilation warning with the compiler's SAVE option disabled and STRING-XREF enabled, the COMPILER system handle reports that ERROR is TRUE, when it should be FALSE.
Lang OCTA-9281 RCODE-INFO results in a COMPILER error when using the COMPILE OPTIONS "require-full-keywords".
Lang OCTA-19917 A memory leak occurs when using objects in the OpenEdge.Net.HTTP package, when passing parameters for an http request.
Lang OCTA-20098 If no password is specified, the ABL session crashes in SET-DB-CLIENT.
Lang OCTA-20221 Getting error: "Failed to find existing object - id 1" when trying to return an Enum value from an AppServer call if the call contains an OUTPUT table parameter as well.
Lang OCTA-6844 WRITE-XMLSCHEMA, and the write-xmlschema option of WRITE-XML, generate XML Schema definitions with ambiguous data when multiple temp-tables in a Dataset have the same XML-NODE-NAME/SERIALIZE-NAME.
Lang OCTA-22713 Memory leak when using an expression that returns a LONGCHAR/MEMPTR as input to a .NET method.
Lang OCTA-29431 Changes to a temp-table's SERIALIZE-NAME are not reflected in WRITE-XML output.
Lang OCTA-2867/PSC00248374 The java open client and .NET open client transpose the values for the classic NameServer retry delay and retry attempt values. An exception with the message may be thrown if the client retry count is out of the expected range:

Invalid NameServer client port retry values. (9366)

Lang OCTA-3100/PSC00319277 Customizing a non-persistent procedure in Proxygen fails if the r-code is compiled with -cpinternal UTF-8 and the code page string is specified in all caps.
Lang OCTA-3299/PSC00343962 When compiling a class with the XREF-XML compiler option, if the class defines a dataset with more than one PARENT-ID-RELATION, the compiler issues the error: Error in DataSet relations information during XREF-XML.
Lang OCTA-3772/PSC00360327 The RadGridView populates records from the parent table, but does not show any child records even though they exist when used with an ABL ProBindingSource and setting the RadGridView:AutoGenerateHierachy property to true.
Lang OCTA-21502 You may get this misleading error if the parent-fields-before value becomes larger than 1024 during READ-JSON() on a DataSet:

ADD-PARENT-ID-RELATION parent-fields-after entry records is not valid. (16030)

Lang OCTA-21588 When compiling ABL classes that pass string constants during the invocation of a constructor or a method and the string-xref compiler option is used, those strings will appear twice in the xref file.
Lang OCTA-22506 A crash can occur when using bufferHandle:DATA-SOURCE-ROWID when the data-source is not defined to use a unique key and there are 2 records in the associated database table with the same key value(s).
Lang OCTA-22552 Grouping is very slow when using the Telerik RadGridView control with the ProBindingSource.
Lang OCTA-22839 When generating .NET proxies that contain strongly typed DataSet or DataTable classes, ProxyGen does not always generate these extended .NET classes correctly on certain machines.

These machines do not have English specified as their default language. In particular, it does not work correctly when the word "version" has a different translation from English to the language on the machine.

Lang OCTA-24489 A memory leak occurs in the use of the AVM's's internal stack after calling the event handler for PROCEDURE-COMPLETE of an asynchronous procedure. If asynchronous procedures are called often enough, the stack size limit will be reached and the following error will be raised:

WARNING: -s stack exceeded. Raising STOP condition and attempting to write stack trace to procore file. Consider increasing -s startup parameter.

The same can happen when running handlers for Sonic Adapter messages.

Lang OCTA-21257 When using the JsonObject WRITE method with character data types there is a memory leak in the client session.
Lang OCTA-14980/PSC00357006 Pas agent is getting terminated when selecting a node in Debug tree view for ABL Data Object webspeed service.
Lang OCTA-17036 PDSOE debugger crashes appsever agent when selecting variables view.
Lang OCTA-21749 Enabling PROFILER crashes AVM in OpenEdge 12.2
OEM OCTA-23935/ADAS-22459 Error when starting PASOE with 16 agents using OEE.
OEM OCTA-23922/ADAS-24159 Unable to change the WebServer configuration from OpenEdge Management console for Linux platforms. For instance, updating the port details results in the error message “Failed to save web server configuration: set webserver config psc.as.http.port failed with non-zero exit value: 51: cannot delete/modify a read-only or runtime restricted property - psc.as.http.port”
OEM OCTA-23969/ADAS-24067 CDC-table list not showing all CDC-policies in OpenEdge Management Console. Out of 3 policies i.e., cdc_douanekode, cdc_histSupplierPrice, cdc_supplierprice the last policy is missing in the list.
OEM OCTA-23981/ADAS-22838 OpenEdge Management does not recognize a war file when deploying an application if that extension is in uppercase.
OEM OCTA-24127/ADAS-18632 PASOE instance does not autostart when AdminServer service started or restarted. It requires a manual intervention to start PASOE instance despite of the setting “autostart=true” in pasmgr.properties file for respective PASOE instance.
OEM OCTA-24143/ADAS-21069 Oldest transaction age - metric value under managed database operational views shows blank in OpenEdge Management console, no matter whether there are active transactions happening or not.
PASOE OCTA-22864 PAS for OpenEdge agent crashes when the DECRYPT function is called with the wrong key.
PASOE OCTA-23956/ADAS-22626 PASOE operation system command "wc -c " on AIX/Linux takes long time to execute.
PASOE OCTA-23962/ADAS-24752 Deleting a pasoe instance or executing pasman unregister removes multiple instances from the instances.* file.
PASOE OCTA-24007/ADAS-24149 OEMANAGER rest api fails to provide the agent metrics when PASOE instance started with RO connection to the database.
PASOE OCTA-24116 If minAvailableABLSessions is greater than 1, the PASOE agent may initialize more than the specified numInitialSessions at startup. Depending on the timing of any session startup procedure, it may initialize as many as numInitialSessions + minAvailableABLSessions.
PASOE OCTA-24125/ADAS-8336 Suppress the generation of errors 18318 and 18320 into the PASOE logs.
PASOE OCTA-24134/ADAS-21171 Injecting packets with malicious xml can allow a PAS for OpenEdge instance to return internal PAS NetworkError.
PASOE OCTA-28596/ADAS-22347 Client Sessions get stuck in Request State "Reading" and even lowering the idle session timeout parameter has no impact on the behavior.
PASOE OCTA-29002 PASOE instance can't be stopped in the production environment with TCMAN STOP command.
PASOE OCTA-29028 Getting error Message: Error on connectRq(): com.progress.appserv.broker.exception.BrokerException$NoAvailableConnectionsException: Agent.
PASOE OCTA-24123/ADAS-23862 Output datasets sent over Soap are not mapped correctly when their name is different than what the WSDL document specifies.
PASOE OCTA-24158/ADAS-23649 PASOE agent disconnects the database and shuts down if a bound apsv session-managed connect procedure returns an error after binding the connection.
PDSOE OCTA-24132 The project's physical path is by default written to the ubpf.config(changed to build.config) file due to which the same project gets errors in other machines.
PDSOE OCTA-28308 java.util.ConcurrentModificationException when using PDSOE plugin APIs for DB interactions.
STAT OCTA-24003/ADAS-21882 Failed SSL connection is preventing new SSL connections to the database under Linux.
Security OCTA-23958/ADAS-21920 Socket -sslciphers, -sslprotocols, -servername and other SSL options are ignored for TCP-STARTTLS.