OCSP Configuration
- Last Updated: December 10, 2024
- 2 minute read
- LoadMaster
- LoadMaster LTSF
- Documentation
OCSP Server
The address of the OCSP server. This can either be in IP address or Fully Qualified Domain Name (FQDN) format.
OCSP Server Port
The port of the OCSP server.
OCSP URL
The URL to access on the OCSP server.
Use SSL
Select this to use SSL to connect to the OCSP server.
Allow Access on Server Failure
Treat an OCSP server connection failure or timeout as if the OCSP server had returned a valid response, that is, treat the client certificate as valid.
OCSP Checking
Select the Enable OCSP Checking check box to enable the LoadMaster to perform OCSP checks on certain outbound connections. This is disabled by default.
Enable OCSP Stapling
If the Enable OCSP Stapling check box is enabled, the LoadMaster verifies certificates for all external connections originated by the LoadMaster (except for re-encrypted connections to the Real Servers). Select this check box to enable the LoadMaster to respond to OCSP stapling requests. If a client connects using SSL and asks for an OCSP response, this is returned. Only Virtual Service certificates are validated. The system holds a cache of OCSP responses that are sent back to the client. This cache is maintained by the OCSP daemon. When the OCSP daemon sends a request to the server, it uses the name specified in the certificate (in the Authority Information Access field). If it cannot resolve this name, then it uses the default OCSP server specified in the OCSP Server text box.
OCSP Refresh Interval
Specify how often the LoadMaster should refresh the OCSP stapling information. The OCSP daemon caches the entry for up to the amount of time specified here, after which it is refreshed. Valid values range from 1 hour (default) to 24 hours.