Powered by Zoomin Software. For more details please contactZoomin

DataDirect ODBC ReadMe

Sybase IQ ODBC 8.0.2 Windows

  • Last Updated: May 8, 2026
  • 9 minute read
    • OpenAccess SDK
    • Documentation

     README
     Progress(R) DataDirect(R)
     Progress DataDirect for ODBC for Sybase IQ Wire Protocol Driver 

     Windows Platforms (32- and 64-bit)
     Release 8.0.2
     February 2026

***********************************************************************
Copyright (C) 2026 Progress Software Corporation and/or its 
subsidiaries or affiliates. All Rights Reserved.
  
***********************************************************************

This README file contains information for Progress(R) DataDirect(R)  
for ODBC for Sybase IQ(TM) Wire Protocol Driver. 

This README file contains information not included in the PROGRESS 
DATADIRECT FOR ODBC FOR SYBASE IQ WIRE PROTOCOL DRIVER USER'S GUIDE.



CONTENTS

Post-GA Product Announcements
Requirements
Installation Directory 
Data Source and Platform Support 
Release 8.0.2 Features
Driver WorkAround Options
Notes, Known Problems, and Restrictions
Documentation
Installed Files for the 32-bit Driver
Installed Files for the 64-bit Driver 


   Post-GA Product Announcements

The readme files will no longer be updated with product announcements and new 
features after the General Availability (GA) of the product. For the latest 
updates and enhancements, please refer to the release notes 
(https://www.progress.com/datadirect-connectors/whats-new).


    Requirements

* The installer program requires a JVM that is Java SE 11 or higher, including
  Oracle JDK, OpenJDK, and IBM SDK (Java) distributions.

* The driver requires the following runtime library:
  Microsoft Visual C/C++ runtime version 14.40.33810 or higher

* IMPORTANT: You must have the Microsoft Data Access Components (MDAC) 
  installed to use this product.
 
  - For 32-bit Windows systems, version 2.6 or higher is required.
  - For 64-bit Windows systems, version 2.8 or higher is required.

  Depending on the version of your Windows operating system, these 
  components may already be installed. You can download a utility that 
  determines whether MDAC is installed and its version from the following
  Microsoft site:

  http://msdn.microsoft.com/en-us/data/aa937730.aspx

  You can also download MDAC from the same site.
    
    
        Installation Directory 

* The default installation directory for the 32-bit driver on a 64-bit 
  system is:

  C:\Program Files (x86)\Progress\DataDirect\ODBC

* The default installation directory for all other installations is:

  C:\Program Files\Progress\DataDirect\ODBC


    Data Source and Platform Support

For the latest data source and platform support information, refer to the 
Product Compatibility Guide: 
https://docs.progress.com/bundle/datadirect-product-compatibility/resource/
datadirect-product-compatibility.pdf  
  

    Changes Since 8.0.2 Release

Enhancements
------------
* The product package now includes .pdb files. These files contain 
  debugging symbols that can be used for diagnosing and debugging 
  issues in the driver.

* The driver is now compiled with a Visual Studio 2022 compiler for Windows 
  platforms. As a result, you must have Microsoft Visual C/C++ runtime 
  version 14.40.33810 or higher on your machine to run the driver.


* The ICU library files that are installed with the product have been 
  upgraded to version 74.1. As a part of this upgrade, the ICU library 
  file names have changed:
  - For the 32-bit driver: From ivicu28.dll to ivicu.dll
  - For the 64-bit driver: From ddicu28.dll to ddicu.dll

  This upgrade is available starting in build 08.02.1072 of the ICU 
  library files.

Changed Behavior
----------------
* The installer program now requires you to install a JRE that is Java SE 11 or
  higher before running the installer. In earlier versions, the JRE used by the
  installer program was included in the product. However, to avoid potential
  security vulnerabilities, the installer program no longer includes a JRE.
  Instead, the installer program uses the JRE in your environment to allow for
  the most secure version of a JRE to be used.
 
  Notes:
  - This change does not affect the JVM requirements for the driver. For the latest 
    driver requirements, refer to the Product Compatibility Guide:
    https://docs.progress.com/bundle/datadirect-product-compatibility/resource/
    datadirect-product-compatibility.pdf
  - The installer program cannot remove the already installed JRE files from the 
    install directory automatically. Remove them manually.


* When calling the catalog functions in which the catalog name is passed 
  as an argument, the driver now returns an empty result set instead of 
  an error.

* The installer program has been updated to no longer install common components 
  for drivers that do not use them. As a result, the installer program no longer 
  installs the following common components for the Sybase IQ Wire Protocol
  driver: 

  - OpenSSL library files, such as ivopenssl30.dll, ddopenssl30.dll, fips.dll, 
    and openssl.cnf.
  - Curl library files, such as ivcurl28.dll and ddcurl28.dll.  

  If the files are not used by any other DataDirect driver on your machine, you 
  can safely remove them from existing product directories.  

    Release 8.0.2 Features

* The driver has been enhanced to include timestamp in the internal packet logs 
  by default. If you want to disable the timestamp logging in packet logs, set 
  PacketLoggingOptions=1. The internal packet logging is not enabled by default. 
  To enable it, set EnablePacketLogging=1. 

Changed Behavior
----------------
* The following Windows platforms have reached the end of their product lifecycle
  and are no longer supported by the driver:
  - Windows 8.0 (versions 8.1 and higher are still supported)
  - Windows Vista (all versions)
  - Windows XP (all versions)
  - Windows Server 2003 (all versions)


    Driver WorkAround Options

Progress DataDirect has included non-standard connection options (workarounds)
for the driver that enable you to take full advantage of packaged ODBC-enabled
applications requiring non-standard or extended behavior. Refer to the chapter
"WorkAround options" in THE PROGRESS DATADIRECT FOR ODBC DRIVERS REFERENCE for 
a description of these options.


     Notes, Known Issues, and Restrictions

Workaround for code page conversion error
------------------------------------------
When the LoadTableFromFile() function is called, if the code page value specified 
in the configuration file, which is passed as an argument in LoadTableFromFile(), 
is different from the default code page value of the machine, the value set for 
the IANAAppCodePage connection attribute is replaced with it.

This change may cause the driver to return the following error: "String data code 
page conversion failed." To work around it, set the SQL_ATTR_IANA_APP_CODE_PAGE 
statement attribute to the code page value specified in the configuration file.

Specifying values for the same connection option multiple times
--------------------------------------------------------------- 
The driver does not support specifying values for the same connection 
option multiple times in a connection string or DSN. If a value is 
specified using the same attribute multiple times or using both 
long and short attributes, the connection may fail or the driver may 
not behave as intended.

126 Error When Modifying Data Sources on Windows 10
---------------------------------------------------
You may receive a 126 error when adding or configuring a data source stored
on a network location. This is caused by the settings of the User Account 
Control (UAC) security feature on Windows 10. To work around this issue:

Important: Implementing this fix disables security safeguards that are designed
to protect your machine. Before starting, refer to the following Microsoft 
documentation for potential risks associated with disabling the UAC feature:  
http://windows.microsoft.com/en-us/
windows/what-are-user-account-control-settings

1.  From the Start menu, type regedit in the search field; then, select regedit
    from the results list. The Registry Editor window opens. 

2.  Navigate to the following registry subkey: 

HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\System

3.  Right-click on the subkey; then, select New > DWORD Value. 

4.  Rename the new value EnableLinkedConnections. 

5.  Right-click EnableLinkedConnections, and then click Modify. The Edit DWORD 
    Value window opens. 

6.  In the Value data field, type 1. Click OK. 

7.  Close the Registry Editor; then, restart your computer. 
  
ODBC Development on Windows Platforms
--------------------------------------
Please read the notices.txt file in the installation directory for 
licensing information regarding the ODBC Core Components. Contact your 
Progress DataDirect representative if you have any questions.
  
SQLColAttribute(s)
------------------
The column attributes 1001 and 1002, which were assigned as DataDirect- 
specific attributes, were inadvertently used as system attributes by
the Microsoft 3.0 ODBC implementation. Applications using those 
attributes must now use 1901 and 1902, respectively.
 
SQL_C_NUMERIC
-------------
Because of inconsistencies in the ODBC specification, users attempting 
to use SQL_C_NUMERIC parameters must set the precision and scale values 
of the corresponding structure and the descriptor fields in the 
Application Parameter Descriptor.
 
For Developers Using IIS
------------------------
One of the most common connectivity issues encountered while using IIS 
(Microsoft's Internet Information Server) concerns the use and settings 
of the account permissions. If you encounter problems using DataDirect 
drivers with an IIS server, refer to KnowledgeBase document number 4274 
on the Progress DataDirect web site:

http://knowledgebase.datadirect.com.
 
For Microsoft Access Users
--------------------------
Some SQL implementations, such as PROGRESS, do not allow queries to 
contain the COUNT function without the DISTINCT set quantifier. For 
example, "SELECT COUNT(empid) FROM employees" is not a valid SQL query 
for PROGRESS. This type of query can be generated using Microsoft 
Access and results in an error. 


    Documentation

PROGRESS DATADIRECT FOR ODBC FOR SYBASE IQ WIRE PROTOCOL DRIVER 
DOCUMENTATION SET
----------------------------------------------------------------
The user's guide is available as an HTML help system on the DataDirect 
documentation web page:

https://docs.progress.com/category/datadirect-sybase-iq

You can also launch the help system by clicking the Help button in the 
Setup dialog box.


     Installed Files for the 32-bit Driver

This file list assumes a full installation of the driver and 
documentation.

The installer copies the following file to the Windows system 
directory:

ivtrc28.dll           DataDirect trace library

The installer copies the following files and subdirectories to the 
product installation directory, by default:

For the 32-bit driver on 64-bit machines:

  C:\Program Files (x86)\Progress\DataDirect\ODBC

For all other installations:

  C:\Program Files\Progress\DataDirect\ODBC

\<install_dir>\:
----------------  
license.txt                       Progress DataDirect license agreement


\drivers\:
---------
ivicu.dll                         Unicode conversion tables
ivicu.pdb                         Debugging symbols for ICU library
ivsyiq28.dll                      Sybase IQ Wire Protocol Driver
ivsyiq28.pdb                      Debugging symbols for Sybase IQ Wire 
                                  Protocol Driver
ivsyiq28r.dll                     Sybase IQ Wire Protocol Driver
                                  resource file     
IVODBC.LIC                        DataDirect license file
ivtrc28.dll                       DataDirect trace library
ivtrc28.pdb                       Debugging symbols for DataDirect trace library  
qesqlext.h                        Header file for DataDirect-specific ODBC 
                                  Definitions               


\FIXES\: 
-------- 
fixes8.0.txt                      List of fixes since last release

                               
\help\:
------
*.html                            HTML redirects to online connector help systems
                                  and documentation resources


\install\: 
--------- 
*.*                               Files associated with the installer program


\NOTICES\:
---------
ODBC for Sybase IQ v8.0 
notices.txt                       Third-party vendor license agreements


\READMES\:
---------
ODBC for Sybase IQ v8.0 
readme.txt                        This file


\samples\bulk\:
--------------
bulk.c                            Bulk example source
bulk.exe                          Bulk application
bulk.mak                          Bulk example make file
bulk.sln                          Bulk example solution file
bulk.vcproj                       Bulk example project file
ddlogging.properties              Log configuration file for the
                                  Sybase IQ driver


\samples\bulkstrm\:
------------------                       
bulk.cpp                          Bulk streaming example source
bulk.hpp                          Bulk streaming example header
bulk.rc                           Bulk streaming example resource file
bulkstreaming.sln                 Bulk streaming example solution file
bulkstreaming.vcproj              Bulk streaming example project file
bulkstrm.exe                      Bulk streaming example application
bulkstrm.txt                      Bulk streaming description
msgprintf.hpp                     Bulk streaming example header file
ProgressDataDirect.bmp
ProgressDataDirect.ico
winmain.cpp                       Bulk streaming example source file
ddlogging.properties              Log configuration file for the
                                  Sybase IQ driver


\samples\example\:
-----------------
example.c                         Example source
Example.exe                       Example application
example.h                         Example header
Example.sln                       Example solution file
Example.vcxproj                   Example project file
ddlogging.properties              Log configuration file for the
                                  Sybase IQ driver


\samples\translat\:
-----------------
LIBMAIN.C                 
README.TRN                        Translation Library example description
TRANSLAT.C                        Translation Library example source file
WINNT.MAK                         Translation Library example make file


\tools\:
-------
ddextwin.exe                      License Extender utility
ddprocinfo.exe                    Processor Information utility
DSNConverterSil.exe               Data Source Converter utility
XMLP.exe                          A GUI demo tool that persists a result set
                                  to an XML data file


\tools\Tableau\:
----------------
DataDirect Sybase IQ.tdc          Tableau data source file   

                                
\uninstall\:
-----------
*.*                               Files used to uninstall the product


    Installed Files for the 64-bit Driver

This file list assumes a full installation of the driver and its
documentation. 

The installer copies the following file to the Windows system 
directory:

ddtrc28.dll           DataDirect trace library

The installer copies the following files and subdirectories to the 
product installation directory, by default:

   C:\Program Files\Progress\DataDirect\ODBC:   
        
\<install_dir>\:
----------------
license.txt                       Progress DataDirect license agreement

 
\drivers\:
---------
ddicu.dll                         Unicode conversion tables
ddicu.pdb                         Debugging symbols for ICU library
ddsyiq28.dll                      Sybase IQ Wire Protocol Driver
ddsyiq28.pdb                      Debugging symbols for Sybase IQ Wire 
                                  Protocol Driver
ddsyiq28r.dll                     Sybase IQ Wire Protocol Driver 
                                  resource file     
DDODBC.LIC                        DataDirect license file
ddtrc28.dll                       DataDirect trace library
ddtrc28.pdb                       Debugging symbols for DataDirect trace library
qesqlext.h                        Header file for DataDirect-specific ODBC 
                                  Definitions


\FIXES\: 
-------- 
fixes8.0.txt                      List of fixes since last release

                                  
\help\:
------
*.html                            HTML redirects to online connector help systems
                                  and documentation resources


\install\: 
--------- 
*.*                               Files associated with the installer program


\NOTICES\:
---------
ODBC for Sybase IQ v8.0
notices.txt                       Third-party vendor license agreements


\READMES\:
---------
ODBC for Sybase IQ v8.0
readme.txt                        This file


\samples\bulk\:
---------------
bulk.c                            Bulk example source
bulk.exe                          Bulk application
bulk.mak                          Bulk example make file
bulk.sln                          Bulk example solution file
bulk.vcproj                       Bulk example project file
ddlogging.properties              Log configuration file for the
                                  Sybase IQ driver
                       

\samples\bulkstrm\:
-------------------
bulk.cpp                          Bulk streaming example source
bulk.hpp                          Bulk streaming example header
bulk.rc                           Bulk streaming example resource file
bulkstreaming.sln                 Bulk streaming example solution file
bulkstreaming.vcproj              Bulk streaming example project file
bulkstrm.exe                      Bulk streaming example application
bulkstrm.txt                      Bulk streaming description
msgprintf.hpp                     Bulk streaming example header file
ProgressDataDirect.bmp
ProgressDataDirect.ico
winmain.cpp                       Bulk streaming example source file
ddlogging.properties              Log configuration file for the
                                  Sybase IQ driver


\samples\example\:
------------------
example.c                         Example source
Example.exe                       Example application
example.h                         Example header
Example.mak                       Example make file
Example.sln                       Example solution file
Example.vcxproj                   Example project file
ddlogging.properties              Log configuration file for the
                                  Sybase IQ driver


\samples\translat\:
-----------------
LIBMAIN.C                 
README.TRN                        Translation Library example description
TRANSLAT.C                        Translation Library example source file
WINNT.MAK                         Translation Library example make file


\tools\:
-------
ddextwin.exe                      License Extender utility
ddprocinfo.exe                    Processor Information utility
DSNConverterSil.exe               Data Source Converter utility
XMLP.exe                          A GUI demo tool that persists a result set to
                                  an XML data file


\tools\Tableau\:
----------------
DataDirect Sybase IQ.tdc          Tableau data source file    

                                
\uninstall\:
------------
*.*                               Files used to uninstall the product


~~~~~~~~~~~~~~~~
February 2026
End of README

TitleResults for “How to create a CRG?”Also Available inAlert