Configuring Trend Micro IWSVA
- Last Updated: April 8, 2022
- 3 minute read
Trend Micro InterScan Web Security Virtual Appliance (IWSVA) supports the ICAP protocol. To integrate IWSVA as your antivirus engine for MOVEit Transfer, follow the guidelines in this section.
Before You Begin
These settings need to be applied at IWSVA:
- IWSVA needs to be configured in ICAP mode.
- The ICAP
X-Infection-Foundresponse header option must be enabled. - For testing purposes, you can adjust the
infected_block_url_lengthto have a very short period (otherwise, the default is four hours). See Trend Micro documentation for details.
Considerations when Testing Content Screening Integration with IWSVA
After you configure Trend Micro IWSVA as a content scanner for MOVEit Transfer (SETTINGS > System > Content Scanning), use the Test Content Scanning feature to upload a test file with a generated virus.
Content Scanning Dialog (Test Content Scanning button shown)

violation) indicated and the WebUI test
results will indicate a fail. The following Test Content Scanning result
message demonstrates what happens when two tests are run within the time window
defined by infected_block_url_length. The first loads the test
virus successfully. The second reflects the blocked event from the scanner (because
there is no violation identified).
First Test Content Scanning Results
|
Second Test Content Scanning Results (within IWSVA Block Time Interval)
|
Checking Debug Logs for Test Content Scanning Results
If you run a test more than once and the previous virus
test file URL (in this case to the generated virus test file) is recognized by
IWSVA, the file will show up as a blocked virus in the MOVEit Transfer
logs, but the named value for Violation will not be present. In
otherwords, the scanner blocks the file upload completely and without repeating the
scan. This is default behavior for Trend Micro IWSVA, which you can change by
adjusting the infected_block_url_length to have a very short
period. See Trend Micro documentation for details are as. The following excerpt
(C:\MOVEitTransfer\web.log) shows how a file that is blocked by IWSVA looks like in
the MOVEit Transfer debug logs.
Debug Log Output from a First Test Content Scanning Run
2019-01-04 17:00:28.1710b0 #33 z60: DoReadQuery: Returned non-empty recordset in 0 ms2019-01-04 17:00:28.2110b0 #33 z50: CScan output: No filename given; using EICAR test string.2019-01-04 17:00:28.2110b0 #33 z50: CScan output: ** AV Violation Detected!2019-01-04 17:00:28.2110b0 #33 z50: CScan output: Violation=Eicar_test_file2019-01-04 17:00:28.2110b0 #33 z50: CScan output: Engine=IWSVA 6.5-SP2_Build_Linux_1548 $Date: 11/04/2015 16:06:48 PM$2019-01-04 17:00:28.2110b0 #33 z50: CScan output: ISTag=11.0-14.729.00-3.100.1027-1.0Debug Log Output from a Second Test Content Scanning Run within the infected_block_url_length Time Window
2019-01-03 10:16:45.82 158 #15 z50: CScan output: No filename given; using EICAR test string.2019-01-03 10:16:45.82 158 #15 z50: CScan output: ** AV Violation Detected!2019-01-03 10:16:45.82 158 #15 z50: CScan output: Violation=2019-01-03 10:16:45.82 158 #15 z50: CScan output: Engine=IWSVA 6.5-SP2_Build_Linux_1548 $Date: 11/04/2015 16:06:48 PM$2019-01-03 10:16:45.82 158 #15 z50: CScan output: ISTag=11.0-14.727.00-3.100.1027-1.0